JK16
IH=Hold current:maximumcurrent at which the device will not trip at 25℃ still air. IT=Trip current:minimumcurrent at which the device will nalways at 25℃ still air. Vmax=Maximum voltagedevice can withstand without damage at rated current. Imax=Maximum faultcurrent device can withstand tithout damage at rated voltage. Ttrip=Maximum time totrip(s) at assigned current. Pd=Typical powerdissipation:typical amount of power dissipated by the decice when in state airenvironment. Rmin=Minimum deviceresistance at 25℃ prior to tripping. Rmax=Maximum deviceresistance at 25℃ prior to tripping.
seo:
category:
DIP
Attachment:

TEL:
JK16
Model |
IHold (A) |
ITrip (A) |
Vmax |
Imax |
Pd Max |
Maximum Time to Trip |
Nominal resistance(mΩ) |
||
V(DC) |
A |
W |
Current(A) |
Time(S) |
Rmin |
Rmax |
|||
JK16-010(T) |
0.1 |
0.3 |
16 |
100 |
0.38 |
0.5 |
5 |
1500 |
7500 |
JK16-025(T) |
0.25 |
0.5 |
16 |
100 |
0.45 |
1.25 |
5 |
500 |
1950 |
JK16-030(T) |
0.3 |
0.6 |
16 |
100 |
0.49 |
1.5 |
5 |
300 |
700 |
JK16-050(T) |
0.5 |
1.0 |
16 |
100 |
0.56 |
2.5 |
5 |
200 |
500 |
JK16-075(T) |
0.75 |
1.5 |
16 |
100 |
0.72 |
3.75 |
5 |
100 |
260 |
JK16-090(T) |
0.9 |
1.8 |
16 |
100 |
0.83 |
4.5 |
5 |
90 |
180 |
JK16-110(T) |
1.1 |
2.2 |
16 |
100 |
0.94 |
5.5 |
5 |
60 |
150 |
JK16-135(T) |
1.35 |
2.7 |
16 |
100 |
1.2 |
6.75 |
5 |
40 |
130 |
JK16-160(T) |
1.6 |
3.2 |
16 |
100 |
1.4 |
8 |
5 |
40 |
110 |
JK16-200(T) |
2 |
4 |
16 |
100 |
2.2 |
6 |
15 |
35 |
75 |
JK16-300 |
3 |
6 |
16 |
100 |
2.3 |
9 |
15 |
20 |
60 |
JK16-400 |
4 |
8 |
16 |
100 |
2.4 |
12 |
15 |
20 |
40 |
JK16-500 |
5 |
10 |
16 |
100 |
2.6 |
15 |
15 |
14 |
25 |
JK16-600 |
6 |
12 |
16 |
100 |
2.8 |
18 |
15 |
10 |
21 |
JK16-700 |
7 |
14 |
16 |
100 |
3.0 |
21 |
15 |
8 |
15 |
JK16-800 |
8 |
16 |
16 |
100 |
3.0 |
24 |
15 |
6 |
13 |
JK16-900 |
9 |
18 |
16 |
100 |
3.3 |
27 |
25 |
4 |
12 |
JK16-1000 |
10 |
20 |
16 |
100 |
3.7 |
30 |
30 |
4 |
11 |
JK16-1100 |
11 |
22 |
16 |
100 |
3.7 |
33 |
30 |
3 |
9 |
JK16-1200 |
12 |
24 |
16 |
100 |
4.2 |
36 |
30 |
3 |
8 |
JK16-1300 |
13 |
26 |
16 |
100 |
4.2 |
39 |
50 |
3 |
8 |
JK16-1400 |
14 |
28 |
16 |
100 |
4.2 |
40 |
50 |
3 |
7 |
IH=Hold current:maximumcurrent at which the device will not trip at 25℃ still air.
IT=Trip current:minimumcurrent at which the device will nalways at 25℃ still air.
Vmax=Maximum voltagedevice can withstand without damage at rated current.
Imax=Maximum faultcurrent device can withstand tithout damage at rated voltage.
Ttrip=Maximum time totrip(s) at assigned current.
Pd=Typical powerdissipation:typical amount of power dissipated by the decice when in state airenvironment.
Rmin=Minimum deviceresistance at 25℃ prior to tripping.
Rmax=Maximum deviceresistance at 25℃ prior to tripping.
previous
no
next
Online message
* note: please be sure to enter accurate information, and keep the communication open, we will contact you as soon as possible